поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

DS1822 датащи(PDF) 5 Page - Maxim Integrated Products

номер детали DS1822
подробное описание детали  Econo 1-Wire Digital Thermometer
Download  21 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  MAXIM [Maxim Integrated Products]
домашняя страница  https://www.maximintegrated.com/en.html
Logo MAXIM - Maxim Integrated Products

DS1822 датащи(HTML) 5 Page - Maxim Integrated Products

  DS1822 Datasheet HTML 1Page - Maxim Integrated Products DS1822 Datasheet HTML 2Page - Maxim Integrated Products DS1822 Datasheet HTML 3Page - Maxim Integrated Products DS1822 Datasheet HTML 4Page - Maxim Integrated Products DS1822 Datasheet HTML 5Page - Maxim Integrated Products DS1822 Datasheet HTML 6Page - Maxim Integrated Products DS1822 Datasheet HTML 7Page - Maxim Integrated Products DS1822 Datasheet HTML 8Page - Maxim Integrated Products DS1822 Datasheet HTML 9Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 21 page
background image
DS1822
5 of 21
OPERATION—ALARM SIGNALING
After the DS1822 performs a temperature conversion, the temperature value is compared to the user-
defined two’s complement alarm trigger values stored in the 1-byte TH and TL registers (see Figure 3).
The sign bit (S) indicates if the value is positive or negative: for positive numbers S = 0 and for negative
numbers S = 1. The TH and TL registers are NV (EEPROM) so they will retain data when the device is
powered down. TH and TL can be accessed through bytes 2 and 3 of the scratchpad as explained in the
MEMORY section of this data sheet.
TH AND TL REGISTER FORMAT Figure 3
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
S
2
6
2
5
2
4
2
3
2
2
2
1
2
0
Only bits 11 through 4 of the temperature register are used in the TH and TL comparison since TH and TL
are 8-bit registers. If the measured temperature is lower than or equal to TL or higher than or equal to TH,
an alarm condition exists and an alarm flag is set inside the DS1822. This flag is updated after every
temperature measurement; therefore, if the alarm condition goes away, the flag will be turned off after the
next temperature conversion.
The master device can check the alarm flag status of all DS1822s on the bus by issuing an Alarm Search
[ECh] command. Any DS1822s with a set alarm flag will respond to the command, so the master can
determine exactly which DS1822s have experienced an alarm condition. If an alarm condition exists and
the TH or TL settings have changed, another temperature conversion should be done to validate the alarm
condition.
POWERING THE DS1822
The DS1822 can be powered by an external supply on the VDD pin, or it can operate in “parasite power”
mode, which allows the DS1822 to function without a local external supply. Parasite power is very useful
for applications that require remote temperature sensing or that are very space constrained. Figure 1
shows the DS1822’s parasite-power control circuitry, which “steals” power from the 1-Wire bus via the
DQ pin when the bus is high. The stolen charge powers the DS1822 while the bus is high, and some of
the charge is stored on the parasite power capacitor (CPP) to provide power when the bus is low. When the
DS1822 is used in parasite power mode, the VDD pin must be connected to ground.
In parasite power mode, the 1-Wire bus and CPP can provide sufficient current to the DS1822 for most
operations as long as the specified timing and voltage requirements are met (refer to the DC
ELECTRICAL CHARACTERISTICS and the AC ELECTRICAL CHARACTERISTICS sections of this
data sheet). However, when the DS1822 is performing temperature conversions or copying data from the
scratchpad memory to EEPROM, the operating current can be as high as 1.5mA. This current can cause
an unacceptable voltage drop across the weak 1-Wire pullup resistor and is more current than can be
supplied by CPP. To assure that the DS1822 has sufficient supply current, it is necessary to provide a
strong pullup on the 1-Wire bus whenever temperature conversions are taking place or data is being
copied from the scratchpad to EEPROM. This can be accomplished by using a MOSFET to pull the bus
directly to the rail as shown in Figure 4. The 1-Wire bus must be switched to the strong pullup within
10
μs (max) after a Convert T [44h] or Copy Scratchpad [48h] command is issued, and the bus must be
held high by the pullup for the duration of the conversion (tconv) or data transfer (twr = 10ms). No other
activity can take place on the 1-Wire bus while the pullup is enabled.
The DS1822 can also be powered by the conventional method of connecting an external power supply to
the VDD pin, as shown in Figure 5. The advantage of this method is that the MOSFET pullup is not
required, and the 1-Wire bus is free to carry other traffic during the temperature conversion time.


Аналогичный номер детали - DS1822

производительномер деталидатащиподробное описание детали
logo
Dallas Semiconductor
DS1822 DALLAS-DS1822 Datasheet
268Kb / 20P
   Econo 1-Wire Digital Thermometer
logo
Maxim Integrated Produc...
DS1822 MAXIM-DS1822 Datasheet
252Kb / 21P
   Econo 1-Wire Digital Thermometer
2015
DS1822++ MAXIM-DS1822+ Datasheet
252Kb / 21P
   Econo 1-Wire Digital Thermometer
2015
DS1822+T&R MAXIM-DS1822+T&R Datasheet
252Kb / 21P
   Econo 1-Wire Digital Thermometer
2015
logo
Dallas Semiconductor
DS1822-PAR DALLAS-DS1822-PAR Datasheet
138Kb / 19P
   Econo 1-Wire Parasite-Power Digital Thermometer
More results

Аналогичное описание - DS1822

производительномер деталидатащиподробное описание детали
logo
Dallas Semiconductor
DS1822 DALLAS-DS1822 Datasheet
268Kb / 20P
   Econo 1-Wire Digital Thermometer
logo
Maxim Integrated Produc...
DS1822 MAXIM-DS1822_V01 Datasheet
252Kb / 21P
   Econo 1-Wire Digital Thermometer
2015
logo
Dallas Semiconductor
DS1822-PAR DALLAS-DS1822-PAR_07 Datasheet
212Kb / 19P
   Econo 1-Wire Parasite-Power Digital Thermometer
logo
Maxim Integrated Produc...
DS1822-PAR MAXIM-DS1822-PAR Datasheet
212Kb / 19P
   Econo 1-Wire Parasite-Power Digital Thermometer
101107
logo
Dallas Semiconductor
DS1822-PAR DALLAS-DS1822-PAR Datasheet
138Kb / 19P
   Econo 1-Wire Parasite-Power Digital Thermometer
DS1720 DALLAS-DS1720 Datasheet
77Kb / 12P
   Econo . Digital Thermometer and Thermostat
logo
Maxim Integrated Produc...
DS18B20 MAXIM-DS18B20_08 Datasheet
261Kb / 22P
   1-Wire Digital Thermometer
REV: 042208
logo
Dallas Semiconductor
DS1820 DALLAS-DS1820 Datasheet
151Kb / 27P
   1-Wire Digital Thermometer
logo
TelCom Semiconductor, I...
TC625 TELCOM-TC625 Datasheet
68Kb / 2P
   1-WIRE DIGITAL THERMOMETER
logo
Dallas Semiconductor
DS18B20X DALLAS-DS18B20X Datasheet
184Kb / 21P
   Flipchip 1-Wire Digital Thermometer
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21


датащи скачать

Go To PDF Page


ссылки URL




Конфиденциальность
ALLDATASHEETRU.COM
Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com