10 / 16 page ADM1023 http://onsemi.com 10 Table 3. List of ADM1023 Registers Read Address (Hex) Write Address (Hex) Name Power−On Default Not applicable Not applicable Address pointer Undefined 00 Not applicable Local temperature value 1000 0000 (0x80) (−128 °C) 01 Not applicable Remote temperature value high byte 1000 0000 (0x80) (−128 °C) 02 Not applicable Status Undefined 03 09 Configuration 0000 0000 (0x00) 04 0A Conversion rate 0000 0010 (0x02) 05 0B Local temperature high limit 0111 1111 (0x7F) (+127 °C) 06 0C Local temperature low limit 1100 1001 (0xC9) (−55 °C) 07 0D Remote temperature high limit high byte 0111 1111 (0x7F) (+127 °C) 08 0E Remote temperature low limit high byte 1100 1001 (0xC9) (−55 °C) Not applicable 0F (Note 1) One−shot 10 Not applicable Remote temperature value low byte 0000 0000 11 11 Remote temperature offset high byte 0000 0000 12 12 Remote temperature offset low byte 0000 0000 13 13 Remote temperature high limit low byte 0000 0000 14 14 Remote temperature low limit low byte 0000 0000 19 Not applicable Reserved 0000 0000 20 21 Reserved Undefined FE Not applicable Manufacturer device ID 0100 0001 (0x41) FF Not applicable Die revision code 0011 xxxx (0x3x) 1. Writing to Address 0F causes the ADM1023 to perform a single measurement. It is not a data register as such; thus, it does not matter what data is written to it. Table 4. Offset Values Offset Registers Remote Temperature 0x11 0x12 Offset Value With Offset Without Offset 1111 1100 0000 0000 −4 °C 14 °C 18 °C 1111 1111 0000 0000 −1 °C 17 °C 18 °C 1111 1111 1110 0000 −0.125 °C 17.875 °C 18 °C 0000 0000 0000 0000 0 °C 18 °C 18 °C 0000 0000 0010 0000 +0.125 °C 18.125 °C 18 °C 0000 0001 0000 0000 +1 °C 19 °C 18 °C 0000 0100 0000 0000 +4 °C 22 °C 18 °C Status Register Bit 7 of the status register (see Table 5) indicates that the ADC is busy converting when it is high. Bit 6 to Bit 3 are flags indicating the results of the limit comparisons. If the local and/or remote temperature measurement is above the corresponding high temperature limit or below the corresponding low temperature limit, one or more of these flags will be set. Bit 2 is a flag that is set if the remote temperature sensor is open−circuit. These five flags are NOR’d together, so that if any of them are high, the ALERT interrupt latch is set, and the ALERT output goes low. Reading the status register clears the five flag bits, provided the error conditions that caused the flags to be set have gone away. While a limit comparator is tripped due to a value register containing an out−of−limit measurement or the sensor is open−circuit, the corresponding flag bit cannot be reset. A flag bit can be reset only if the corresponding value register contains an in−limit measurement, or the sensor is good. The ALERT interrupt latch is not reset by reading the status register, but it resets when the ALERT output has been serviced by the master reading the device address, provided the error condition has gone away and the status register flag bits have been reset. |
Аналогичный номер детали - ADM1023ARQZ |
|
Аналогичное описание - ADM1023ARQZ |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |