поискавой системы для электроныых деталей |
|
TA2-A000-030 датащи(PDF) 7 Page - Magnetrol International, Inc. |
|
TA2-A000-030 датащи(HTML) 7 Page - Magnetrol International, Inc. |
7 / 16 page Materials 316/316L stainless steel all welded Carbon steel with stainless steel sensor Process connections NPT or 150-pound flange – Refer to model number Pressure rating 1500 psig @ +70° F (103 bar @ +20° C), 1100 psig @ +400° F (76 bar @ +200° C) Temperature rating -50° to +400° F (-45° to +200° C) S P E C I F I C A T I O N S P E R F O R M A N C E P R O B E F L O W B O D Y Flow range maximum 10–50,000 SFPM (0.05–250 Nm/s) air reference to standard conditions Contact MAGNETROL for other gases Accuracy flow ±1% of reading +0.5% of calibrated full scale Accuracy temperature ±2° F (1° C) Repeatability ±0.5% of reading Linearity Included in flow accuracy Turn down 100:1 typical (depending on calibrated flow range) Calibration NIST traceable Span Minimum 0–100 SFPM Response time 1 to 3 second time constant typical Cable length 500 feet (150 m); (see page 11 for cable specifications) SIL Safe Failure Fraction (SFF) 88.4% Materials 316/316L stainless steel all welded Hastelloy® C-276 Process connections Refer to model number, hot tap optional Process Pressure 1500 psig @ +70° F (103 bar @ +20° C), 1375 psig @ +400° F (95 bar @ +200° C) Temperature rating -50° to +400° F (-45° to +200° C) Display Two-line alphanumeric LCD, 16 characters per line Keypad Four push button Menu Language English, French, German, Spanish, Russian Supply voltage 100–264 VAC, 50–60 Hz 11.6– 30 VDC (11.6 VDC requires integral electronics) Power consumption DC = 6.8 watts, AC = 7 VA typical, 11.9 VA maximum Signal Output 4–20 mA, HART available (3.8 to 20.5 mA useable—meets NAMUR NE 43) Analog output signal Active 4–20 mA (isolated) maximum 1000 Ω loop resistance Passive 4–20 mA (isolated) loop resistance dependent on power supply, 11– 36 VDC Diagnostic Alarm 3.6 mA, 22 mA, HOLD HART Optional Pulse Output Active Connection — 24 VDC (±10%) Power, 150 mA Passive Connection — 2.5 to 60 VDC Power, 1.5 AMP Alarm Output Active Connection — 24 VDC (±10%) Power, 100 mA Passive Connection — 2.5 to 60 VDC Power, 1 AMP Ambient temperature -40° to +176° F (-40° to +80° C); display not readable below -22° F (-30° C) Temperature effect Approximately ±0.04% of reading per ° C Humidity 99% Non-condensing Housing Material Aluminum A356 (<0.2% copper) Shock Vibration ANSI/ISA-S71.03 table 2, level SA1 (Shock), ANSI/ISA-S71.03 table 1, level VC2 (Vibration) For operating temperatures between +250° and +400° F (+120° and +200° C), either use remote electronics or a longer length insertion probe to provide an additional four inches (100 mm) between the electronics and the compression fitting. 7 T R A N S M I T T E R |
Аналогичный номер детали - TA2-A000-030 |
|
Аналогичное описание - TA2-A000-030 |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |