поискавой системы для электроныых деталей |
|
SI8900 датащи(PDF) 4 Page - Silicon Laboratories |
|
SI8900 датащи(HTML) 4 Page - Silicon Laboratories |
4 / 8 page AN637 4 Rev. 0.1 3. Si8900 Auto Baud Master Controller Algorithm Figure 3 shows the master/Si8900 adaptive automatic baud rate detection (“auto baud”). The Si8900 baud rate detection algorithm uses the master's UART baud rate to determine the upper and lower baud rate boundaries and centers the operating baud rate between these two limits. Adaptive baud rate detection begins with the Si8900 setting its baud rate to its maximum value of 520 kbps and waiting for the master to send a stream of bytes (each having a hex value of 0xAA) to the Si8900. The Si8900 compares each received byte to 0xAA and decreases the baud rate when the received byte is other than 0xAA. This process continues until 0xAA is successfully received by the Si8900, at which time the upper baud rate limit value is stored in Si8900 memory. Figure 3. Si8900 Auto Baud Process Functional Flow Diagram The Si8900 then discovers its lower baud rate limit by setting the baud rate to its minimum value of 58 kbps and again comparing each incoming byte to 0xAA, increasing the baud rate until 0xAA is successfully received and stored in Si8900 memory. The Si8900 then optimizes the baud rate by centering the operating baud rate half-way between the upper and lower baud rate limits. The Si8900 then terminates the adaptive baud rate sequence by transmitting two sequential 0x55 bytes to the master. Master controller C-code firmware examples for Figure 3 are available in the application note, “AN635: Si8900 Automatic Baud Rate Detection” available for download at www.silabs.com/isolation. Master Transmit Start Si8900 (Slave) Serial Hex Byte (0xAA) Transmission from Master Decrease Baud Rate ?0xAA Increase Baud Rate ?0xAA No Data =0xAA Upper BR Detect Upper BR Limit Setting Maximum BR Setting Lower BR Detect Lower BR Limit Setting =0xAA Re‐ Transmit Exit Process Center BR ? 0x55, 0x55 Receive Minimum BR Setting No Data Exit Process =0x55, 0x55 Process Complete =0xAA Store Final Setting Validate BR Baud Rate Valid Baud Rate Invalid Reset Clear Registers, Start Over Terminate Process No Data |
Аналогичный номер детали - SI8900 |
|
Аналогичное описание - SI8900 |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |