поискавой системы для электроныых деталей |
|
UC1904 датащи(PDF) 1 Page - Texas Instruments |
|
UC1904 датащи(HTML) 1 Page - Texas Instruments |
1 / 7 page BLOCK DIAGRAM Note: Pin Numbers refer to J, N, and DW Packages. 4/97 The UC1904 Quad Supply Monitor will respond to under- and over-volt- age conditions on up to four continuously monitored voltage levels. Four independent positive voltages can be monitored or, alternatively, two of the sense inputs are preset to monitor -5V and -12V supplies. The de- vice also monitors Over-Current and Line Sense inputs, both with preci- sion input thresholds. Four open collector outputs on the UC1904 give the following re- sponses: 1. The OV/OC output is a latched over-voltage, or over-current response. 2. A Power Good signal responds low with any fault detection – on power-up a programmable delay is used to hold this output low for a system Power On Reset signal. 3. The PWRW output responds only to a Line Sense input, for early warning of power failures. 4. The last open collector, the ON/OFF output, generates a delayed supply OFF control signal in response to an OFF input command, under-voltage condition, or line fault detection. The OV-UV fault window is adjustable with a programming input. The thresholds are centered around the precision 2.5V reference, with a scaled hysteresis for precise, glitch free operation. In the positive mode of operation, the fault windows at each of the sense inputs can be inde- pendently scaled using external resistors and the 2.5V reference output. An Auto Restart function couples with the under-voltage and line sens- ing circuits to allow controlled power supply start-up and shutdown. This device will operate over a supply range of 4.75V to 18V. The device is available in a DIP, SOIC, or PLCC outline. This device is ESD pro- tected on all pins. • Inputs for Monitoring Up to Four Supply Voltages • Two Inputs Preset for -5V and -12V Monitoring, or Programmable Positive Levels • Precision 2.5V Reference • Separate Inputs for Over-Current and Line Fault Sensing • Adjustable Under- to Over-Voltage Fault Windows • Latched Over-Voltage and Over-Current Output • Power Good and Power Warning Outputs • Auto Restart Function with ON/OFF Control, and Programmable Delay • Programmable Pwr On Reset Delay UC1904 UC2904 UC3904 Precision Quad Supply and Line Monitor FEATURES DESCRIPTION |
Аналогичный номер детали - UC1904_08 |
|
Аналогичное описание - UC1904_08 |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |