4 / 10 page Input Speciications The accuracy is given as ± (% of reading + counts of least signiicant digit (LSD)) at 23 °C ± 5 °C, with relative humidity less than 80% R.H. and after a warm-up period of at least ive minutes. Without warm-up, an additional ive counts of LSD need to be considered. Voltage speciications Function Range Resolution Accuracy Overload protection DC voltage1 50 mV 1 µV 0.05% + 502 250 Vrms 500 mV 10 µV 0.03% + 5 5 V 0.1 mV 50 V 1 mV 250 V 10 mV AC voltage3 (True-rms: From 5% to 100% of range) 50 mV 1 µV 45 Hz to 5 kHz: 0.7% + 40 5 kHz to 20 kHz: 1.5% + 40 500 mV 10 µV 45 Hz to 5 kHz: 0.7% + 20 5 kHz to 20 kHz: 1.5% + 20 5 V 0.1 mV 50 V 1 mV 250 V 10 mV AC+DC voltage3 (True-rms: From 5% to 100% of range) 50 mV 1 µV 45 Hz to 5 kHz: 0.8% + 70 5 kHz to 20 kHz: 1.6% + 70 500 mV 10 µV 45 Hz to 5 kHz: 0.8% + 25 5 kHz to 20 kHz: 1.6% + 25 5 V 0.1 mV 50 V 1 mV 250 V 10 mV 1. Input impedance: 10 MΩ (nominal) for the range of 5 V and above, and 1 GΩ (nominal) for the 50/500 mV range. 2. Accuracy can be improved to 0.05% + 5. Always use the Relative function to offset thermal effects before measuring the signal. 3. Input impedance: 1.1 MΩ in parallel with < 100 pF (nominal) for the range of 5 V and above, and 1 GΩ (nominal) for the 50/500 mV range. Crest factor ≤ 3. Current speciications Function Range Resolution Accuracy Burden voltage/shunt Overload protection DC current 50 mA 1 µA 0.03% + 51 0.06 V (1 Ω) 250 V, 630 mA Quick acting fuse 500 mA 10 µA 0.03% + 51 0.6 V (1 Ω) AC current2 (True-rms: From 5% to 100% of range) 50 mA 1 µA 45 Hz to 5 kHz: 0.6% + 20 0.06 V (1 Ω) 500 mA 10 µA 45 Hz to 5 kHz: 0.6% + 20 0.6 V (1 Ω) AC+DC current2 (True-rms: From 5% to 100% of range) 50 mA 1 µA 45 Hz to 5 kHz: 0.7% + 25 0.06 V (1 Ω) 500 mA 10 µA 45 Hz to 5 kHz: 0.7% + 25 0.6 V (1 Ω) 1. Always use the Relative function to offset thermal effects before measuring the signal. If this function is not used, accuracy could go down to 0.03% + 25. Thermal effects may be present due to: – Constant current, constant voltage, or square wave output. – Wrong operation. For example, resistance, diode, or mV measurement function is used to measure high voltage signals exceeding 250 V. – After battery charging has completed. – After measuring current greater than 50 mA. 2. Crest factor ≤ 3. 04 | Keysight | U1401B Handheld Multi-function Calibrator/Meter - Data Sheet |
Аналогичный номер детали - U1401B |
|
Аналогичное описание - U1401B |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |