2 / 7 page cui.com date 02/20/2018 │ page 2 of 7 CUI Inc │ SERIES: VAQE6W-D │ DESCRIPTION: DC-DC CONVERTER INPUT parameter conditions/description min typ max units operating input voltage 24 Vdc input models 48 Vdc input models 9 18 24 48 36 75 Vdc Vdc start-up voltage 24 Vdc input models 48 Vdc input models 9 18 Vdc Vdc surge voltage for maximum of 1 second 24 Vdc input models 48 Vdc input models -0.7 -0.7 50 100 Vdc Vdc under voltage shutdown 24 Vdc input models 48 Vdc input models 5.5 14 6.5 15.5 Vdc Vdc current 24 Vdc input models 3.3 Vdc output models all other models 268 320 mA mA 48 Vdc input models 3.3 Vdc output models all other models 134 154 mA mA filter Pi filter no load power consumption 0.12 W OUTPUT parameter conditions/description min typ max units maximum capacitive load1 3.3, 5 Vdc output models 9 Vdc output models ±12 Vdc output models ±15 Vdc output models all other models 2,200 1,000 330 220 680 μF μF μF μF μF voltage accuracy 5% to full load ±1 ±3 % 0%~5% load single output models dual output models ±1 ±2 ±3 ±5 % % line regulation from low line to high line, full load positive outputs negative outputs ±0.2 ±0.5 ±0.5 ±1 % % load regulation2 from 5% to full load positive outputs negative outputs ±0.5 ±0.5 ±1 ±1.5 % % voltage balance3 dual output models ±0.5 ±1.5 % cross regulation dual output models: main output 50% load secondary output from 10~100% load ±5 % switching frequency4 PWM mode 300 kHz transient recovery time 25% load step change, nominal input voltage 300 500 μs transient response deviation 25% load step change, nominal input voltage ±3 ±5 % temperature coefficient at full load ±0.03 %/°C Note: 1. Tested at input voltage range and full load. 2. At 0~100% load, the max load regulation is ±5%. 3. Unbalanced loads should not exceed ±5%. If ±5% is exceeded, the product performance cannot be guaranteed. 4. Value is based on full load. At loads <50%, the switching frequency decreases with decreasing load. PROTECTIONS parameter conditions/description min typ max units over voltage protection 110 160 % over current protection 24 Vdc output models all other models 110 110 220 140 290 190 % % short circuit protection continuous, self recovery |
Аналогичный номер детали - VAQE6W-Q24-S15-D |
|
Аналогичное описание - VAQE6W-Q24-S15-D |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |