поискавой системы для электроныых деталей |
|
TPA3000D1 датащи(PDF) 11 Page - Texas Instruments |
|
TPA3000D1 датащи(HTML) 11 Page - Texas Instruments |
11 / 19 page TPA3000D1 SLOS379A – SEPTEMBER 2001 – REVISED JANUARY 2002 11 www.ti.com APPLICATION INFORMATION eliminating the output filter with the TPA3000D1 This section focuses on how the user can eliminate the output filter with the TPA3000D1. effect on audio The class-D amplifier outputs a pulse-width modulated (PWM) square wave, which is the sum of the switching waveform and the amplified input audio signal. The human ear acts as a band-pass filter such that only the frequencies between approximately 20 Hz and 20 kHz are passed. The switching frequency components are much greater than 20 kHz, so the only signal heard is the amplified input audio signal. traditional class-D modulation scheme The traditional class-D modulation scheme, which is used in the TPA032D0x family, has a differential output where each output is 180 degrees out of phase and changes from ground to the supply voltage, VCC. Therefore, the differential prefiltered output varies between positive and negative VCC, where filtered 50% duty cycle yields 0 V across the load. The traditional class-D modulation scheme with voltage and current waveforms is shown in Figure 23. Note that even at an average of 0 V across the load (50% duty cycle), the current to the load is high, causing high loss, thus causing a high supply current. 0 V –12 V +12 V Current OUTP Differential Voltage Across Load OUTN Figure 23. Traditional Class-D Modulation Scheme’s Output Voltage and Current Waveforms Into an Inductive Load With No Input TPA3000D1 modulation scheme The TPA3000D1 uses a modulation scheme that still has each output switching from 0 to the supply voltage. However, OUTP and OUTN are now in phase with each other with no input. The duty cycle of OUTP is greater than 50% and OUTN is less than 50% for positive output voltages. The duty cycle of OUTP is less than 50% and OUTN is greater than 50% for negative output voltages. The voltage across the load sits at 0 V throughout most of the switching period, greatly reducing the switching current, which reduces any I2R losses in the load. |
Аналогичный номер детали - TPA3000D1 |
|
Аналогичное описание - TPA3000D1 |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |