3/5
Format #: COTCO-D-074 REV.4
Document No. SPE/LC512TWN1-25G-A1
Rev. No.
01
Standard bins for LC512TWN1-25G-A1 (IF = 20mA):
Lamps are sorted to Luminous Intensity –IV , VF & Chromaticity Coordinates –(X,Y) bins shown.
Orders for LC512TWN1-25G-A1 may be filled with any or all bins contained as below.
All Luminous Intensity –IV , VF & Chromaticity Coordinates –(X,Y) values shown and specified are at IF =20mA.
A
A1
1
A
A2
2
B
B1
1
B
B2
2
cc
12000mcd
8200mcd
Z
5860mcd
Y
4180mcd
X
* X+ indicates Luminous Intensity is at X bin or above.
Rank
A1
A2
B1
x
0.245 0.264 0.280 0.264 0.264 0.283 0.296 0.280 0.283 0.307 0.313 0.296
Chromaticity
Coordinates
y
0.229 0.267 0.248 0.220 0.267 0.305 0.276 0.248 0.305 0.337 0.297 0.276
Rank
B2
c
x
0.307
0.330
0.330
0.313
0.330
0.361
0.356
0.330
Chromaticity
Coordinates
y
0.337
0.360
0.318
0.297
0.360
0.385
0.351
0.318
F
Fo
orrw
wa
arrd
d V
Vo
olltta
ag
ge
e ((V
VFF))
Rank
V6
V7
V8
V9
V10
V11
V12
Voltage
2.6-2.8V
2.8-3.0V
3.0-3.2V
3.2-3.4V
3.4-3.6V
3.6-3.8V
3.8-4.0V
IIm
mp
po
orrtta
an
ntt N
No
otte
es
s::
1) All ranks will be included per delivery, rank ratio will be based on the Dices distribution.
2) Pb content <1000PPM.
3) Tolerance of measurement of luminous intensity is ±15%.
4) Tolerance of measurement of the Color Coordinates is ± 0.015.
5) Tolerance of measurement of Vf is ±0.05 V.
6) Packaging methods are available for selection, Please refer to PACKAGING STANDARD.
7) Please refer to LED LAMP RELIABILITY TEST STANDARD for reliability test conditions.
8) Please refer to APPLICATION NOTES for Application.
* X+
Chromaticity Coordinates (X,Y)