DM220 датащи(PDF) 2 Page - Extech Instruments Corporation.

номер детали DM220
подробное описание детали  Pocket Autoranging DMM
Download  15 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  EXTECH [Extech Instruments Corporation.]
домашняя страница  http://www.extech.com
Logo EXTECH - Extech Instruments Corporation.

DM220 датащи(HTML) 2 Page - Extech Instruments Corporation.

  DM220 Datasheet HTML 1Page - Extech Instruments Corporation. DM220 Datasheet HTML 2Page - Extech Instruments Corporation. DM220 Datasheet HTML 3Page - Extech Instruments Corporation. DM220 Datasheet HTML 4Page - Extech Instruments Corporation. DM220 Datasheet HTML 5Page - Extech Instruments Corporation. DM220 Datasheet HTML 6Page - Extech Instruments Corporation. DM220 Datasheet HTML 7Page - Extech Instruments Corporation. DM220 Datasheet HTML 8Page - Extech Instruments Corporation. DM220 Datasheet HTML 9Page - Extech Instruments Corporation. Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 15 page
background image
DM220 V3.0 01/06
2
Safety
This symbol adjacent to another symbol, terminal or
operating device indicates that the operator must refer to an
explanation in the Operating Instructions to avoid personal
injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous
situation, which if not avoided, could result in death or
serious injury.
This symbol indicates that a device is protected throughout
by double insulation or reinforced insulation.
This meter has been designed for safe use, but must be operated with caution.
The rules listed below must be carefully followed for safe operation.
1.
NEVER apply voltage or current to the meter that exceeds the specified
maximum:
Input Protection Limits
Function
Maximum Input
V DC or V AC
600V DC/AC
µA AC/DC
200mA 500V fast acting resettable fuse
Resistance, Diode Test,
Continuity Test
600V DC/AC
2.
USE EXTREME CAUTION when working with voltages greater than 25VAC
or 35VDC. These voltages are considered a shock hazard.
3.
DO NOT measure voltage if the voltage on the "COM" input jack exceeds
600V above earth ground.
4.
NEVER connect the meter leads across a voltage source while the function
switch is in the current, resistance, or diode mode. Doing so can damage the
meter.
5.
ALWAYS discharge filter capacitors in power supplies and disconnect the
power when making resistance, continuity or diode tests.
6.
ALWAYS turn off the power and disconnect the test leads from the circuit
before opening the cover to replace the batteries.
7.
NEVER operate the meter unless the battery cover is in place and fastened
securely.
Description
1.
Non-contact ACV detector probe tip
2.
Non-contact ACV indicator light
3.
3-3/4 digit (4000 count) LCD
4.
Mode switch
5.
Flashlight button
6.
Function switch
7.
Battery cover
8.
Test Leads
9.
Hz/%Duty Cycle button
10. Flashlight
WARNING
1
2
3
4
5
6
7
8
9
10


Аналогичный номер детали - DM220

производительномер деталидатащиподробное описание детали
logo
RF Monolithics, Inc
DM2200-434VM RFM-DM2200-434VM Datasheet
507Kb / 6P
   RFM VersaMESHTM Versatile Mesh Network Protocol
DM2200-916VM RFM-DM2200-916VM Datasheet
347Kb / 6P
   RFM VersaMESHTM Versatile Mesh Network Protocol
DM2200-916VM-1 RFM-DM2200-916VM-1 Datasheet
347Kb / 6P
   Up to 600 meters Module to Module range
logo
Extech Instruments Corp...
DM220 EXTECH-DM220_15 Datasheet
353Kb / 1P
   CAT IV Pocket MultiMeter
More results

Аналогичное описание - DM220

производительномер деталидатащиподробное описание детали
logo
Extech Instruments Corp...
DM100 EXTECH-DM100 Datasheet
159Kb / 2P
   Pocket Multimeter 4000 Count Autoranging DMM
DM110 EXTECH-DM110 Datasheet
148Kb / 2P
   Pocket Multimeter 4000 Count Autoranging DMM
MN26 EXTECH-MN26 Datasheet
156Kb / 10P
   Mini Autoranging MultiMeter
logo
Powerbox
VI-ARM-C11 POWERBOX-VI-ARM-C11 Datasheet
506Kb / 1P
   AC INPUT - AUTORANGING
logo
List of Unclassifed Man...
UAW125S-12 ETC2-UAW125S-12 Datasheet
169Kb / 3P
   Autoranging input
MS8211 ETC1-MS8211 Datasheet
3Mb / 1P
   PEN-TYPE AUTORANGING
logo
Powerbox
FLATPAC POWERBOX-FLATPAC Datasheet
165Kb / 2P
   Inputs - 115/230VAC autoranging
logo
Extech Instruments Corp...
MN16 EXTECH-MN16 Datasheet
368Kb / 14P
   Autoranging Mini Multimeter
logo
Vicor Corporation
FARM VICOR-FARM Datasheet
314Kb / 12P
   FARM Filter/ Autoranging Rectifier Module
logo
Intersil Corporation
ICL7139 INTERSIL-ICL7139 Datasheet
111Kb / 13P
   33/4 Digit, Autoranging Multimeter
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


датащи скачать

Go To PDF Page


ссылки URL




Конфиденциальность
ALLDATASHEETRU.COM
Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com