7 / 12 page AD670 REV. A –7– Table III. AD670 TIMING SPECIFICATIONS @ +25 C Symbol Parameter Min Typ Max Units WRITE/CONVERT START MODE tW Write/Start Pulse Width 300 ns tDS Input Data Setup Time 200 ns tDH Input Data Hold 10 ns tRWC Read/Write Setup Before Control 0 ns tDC Delay to Convert Start 700 ns tC Conversion Time 10 µs READ MODE tR Read Time 250 ns tSD Delay from Status Low to Data Read 250 ns tTD Bus Access Time 200 250 ns tDH Data Hold Time 25 ns tDT Output Float Delay 150 ns tRT R/W before CE or CS low 0 ns Boldface indicates parameters tested 100% unless otherwise noted. See Specifications page for explanation. 6b. Bipolar 6c. Full Scale (Unipolar) Figure 6. Transfer Curves CONTROL AND TIMING OF THE AD670 Control Logic The AD670 contains on-chip logic to provide conversion and data read operations from signals commonly available in micro- processor systems. Figure 7 shows the internal logic circuitry of the AD670. The control signals, CE, CS, and R/W control the operation of the converter. The read or write function is deter- mined by R/W when both CS and CE are low as shown in Table II. If all three control inputs are held low longer than the conversion time, the device will continuously convert until one input, CE, CS, or R/W is brought high. The relative timing of these signals is discussed later in this section. Figure 7. Control Logic Block Diagram Table II. AD670 Control Signal Truth Table R/W CS CE OPERATION 0 0 0 WRITE/CONVERT 1 0 0 READ X X 1 NONE X 1 X NONE Timing The AD670 is easily interfaced to a variety of microprocessors and other digital systems. The following discussion of the timing requirements of the AD670 control signals will provide the de- signer with useful insight into the operation of the device. Write/Convert Start Cycle Figure 8 shows a complete timing diagram for the write/convert start cycle. CS (chip select) and CE (chip enable) are active low and are interchangeable signals. Both CS and CE must be low for the converter to read or start a conversion. The minimum pulse width, tW, on either CS or CE is 300 ns to start a conversion. |
Аналогичный номер детали - AD670BD |
|
Аналогичное описание - AD670BD |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |