поискавой системы для электроныых деталей |
|
FWA-35A21F датащи(PDF) 10 Page - Cooper Bussmann, Inc. |
|
FWA-35A21F датащи(HTML) 10 Page - Cooper Bussmann, Inc. |
10 / 21 page Ferrule — FWC 600V: 6-32A Dimensions - mm (inches) 38.1 (1.500") 9.5 (0.375") 10.3 (0.406") FWC (10 x 38mm) Specifications Description: Ferrule style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: — 600Vac/dc Amps: — 6-32A IR: — 200kA RMS Sym. — 50kA @ 700Vdc (6-25A) Agency Information: CE, UL Recognition: 6-32A. UL Recognition: 6-25A Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Catalog Numbers Electrical Characteristics Rated I 2t (A2 Sec) Catalog Current Clearing Watts Numbers Size RMS-Amps Pre-arc at 600V Loss FWC-6A10F 6 4 30 1.5 FWC-8A10F 8 6 50 2.0 FWC-10A10F 10 9 70 2.5 FWC-12A10F 10 x 38mm 12 15 120 3.0 FWC-16A10F ( 13⁄32” x 11⁄2”) 16 25 150 3.5 FWC-20A10F 20 34 260 4.8 FWC-25A10F 25 60 390 6.0 FWC-30A10F 30 95 600 7.5 FWC-32A10F 32 95 600 7.5 • Watts loss provided at rated current. • See accessories on page 216. Features and Benefits • Excellent cycling capability and DC performance • Low arc voltage and low energy let-through (I2t) • Low watts loss in a compact size • Used with finger-safe holders/blocks Typical Applications • DC common bus • DC drives • Power converters/rectifiers • Reduced voltage starters 500 600 400 250 100 1.5 1.0 0.5 0.3 0.2 0.15 Eg K UL 2.0 1.6 1.2 103 800 600 500 400 300 400 300 200 500 600 Eg Kp 1.0 0.8 0.4 0.5 0.6 0.3 0.2 0.1 30 40 50 60 70 80 90 100% I b Data Sheet: 720011 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 205 High Speed Fuses |
Аналогичный номер детали - FWA-35A21F |
|
Аналогичное описание - FWA-35A21F |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |