поискавой системы для электроныых деталей |
|
FWJ-2000A датащи(PDF) 2 Page - Cooper Bussmann, Inc. |
|
FWJ-2000A датащи(HTML) 2 Page - Cooper Bussmann, Inc. |
2 / 2 page ® Bussmann® The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Form No. FWJ 1000 Page 2 of 2 BIF Doc #720027 FWJ 1000V 35-2000A A E D C F J G B H Fig. 1: 35-2000 Amp Range Order # Fig. A B C D E F G H J FWJ-35A-60A 1 5.000 0.940 3.110 4.235 4.180 0.352 0.750 0.125 0.380 FWJ-70A-100A 1 4.932 1.125 3.085 4.266 4.156 0.352 1.000 0.188 0.407 FWJ-125A-200A 1 5.685 1.526 3.261 4.803 4.055 0.445 1.000 0.250 0.819 FWJ-250A-400A 1 5.768 2.000 3.500 4.811 4.150 0.433 1.500 0.250 0.764 FWJ-500A-600A 1 7.201 2.500 3.465 5.984 4.706 0.562 2.000 0.375 1.201 FWJ-800A-2000A 1 6.811 3.500 3.312 5.472 4.962 0.625 2.750 0.500 0.880 Dimension in inches. 1mm = 0.0394∑ 1∑ = 25.4mm Dimensions 1000 800 500 200 1.5 1.0 0.5 0.3 0.2 0.15 Eg K 2000 1600 1200 800 400 200 600 1000 1400 1800 U L E g Kp 1.0 0.8 0.4 0.5 0.6 0.3 0.2 0.1 30 40 50 60 70 80 90 100% I b Total Clearing I2t The total clearing I 2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other volt- ages, the clearing I 2t is found by multi- plying by correction factor, K , given as a function of applied working voltage, Eg, (RMS). Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current . The correction factor, Kp , is given as a function of the RMS load current, Ib , in % of the rated current . Electrical Characteristics 7-11-01 SB01191 † |
Аналогичный номер детали - FWJ-2000A |
|
Аналогичное описание - FWJ-2000A |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |