3 / 4 page 6 © Copyright Pico Technology 2008 DO144-1 8. Specifications Bandwidth DC to 50 MHz (-3 dB) Attenuation ratio 1:10 Accuracy ±1% Rise time < 7 ns Input impedance 1.6 M Ω || 7 pF each side to ground Input Voltage Differential Range* ±70 V (DC + Peak AC) or 70 V RMS Common Mode Range* ±700V (DC + Peak AC) or 600 V RMS Absolute Max. Voltage* (either input to ground) ±700 V (DC + Peak AC) or 600 V RMS CAT I Output Swing (into 5 kΩ load) ±7 V Offset (typical) < ±2 mV Noise (typical) 0.7 mV RMS Source impedance (typical) 50 Ω CMRR (typical) -95 dB @ 60 Hz; -60 dB @ 1 MHz Ambient operating temperature -10 to +40 °C Ambient storage temperature -30 to +70 °C Ambient operating humidity 25 to 85% RH Ambient storage humidity 25 to 85% RH Power requirements** Option 1 Mains adaptor (6 V DC 90 mA or 9 V DC 70 mA) Option 2 Removable battery pack (4xAA cells) Option 3 Power leads Optional extension plugs for mains adaptor - Input One jack with 1 A current rating - Output Three plugs with 1 A current rating Length of input leads 50 cm Length of BNC cable 125 cm Weight 300 g Dimension (LxWxH) 111 mm x 22 mm x 14 mm * Voltage limit is the lesser of the DC+Peak AC and RMS values. ** a. The supplied voltage must be less than 16 V and greater than 3.3 V, otherwise the probe could be damaged or might not operate properly. b. Polarity is “+” inside and “–” outside. If the polarity is wrong, a built-in circuit protects the probe so that no danger or damage will occur. c. When the voltage of the cells becomes too low, the power indicator on the panel will flicker. DO144-1 © Copyright Pico Technology 2008 3 Use proper power source To ensure proper functioning of this probe, use four AA cells or a 6 V DC / 90 mA mains adaptor or 9 V DC / 70 mA mains adaptor or power leads. Do not operate the probe if it is damaged If you suspect there is damage to this probe, have it inspected by qualified service personnel. 3. Description By enabling conventional oscilloscopes to display and measure in-circuit waveforms that are referenced to high common-mode voltages, this differential probe extends the measurement capability of oscilloscopes to electronic power converters, inverters, motor speed controls, switch-mode power supplies and many other applications. 4. Installation a. Simply plug in the BNC output connector to the vertical input of a general-purpose oscilloscope or other measurement instrument, and connect the auxiliary grounding terminal to a proper ground. The measurement instrument must have a ground reference. b. Connect an appropriate power source (mains adaptor, battery pack or power lead) to this probe and then turn it on. WARNING To protect against electric shock, use only the accessories designed for use with this differential probe. c. Using the appropriate probe accessories, connect the input to the circuits under measurement. CAUTION This probe is designed for carrying out differential measurements between two points on the circuit under test. It is not intended for electrically insulating the circuit under test and the measuring instrument. |
Аналогичный номер детали - TA058 |
|
Аналогичное описание - TA058 |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |