поискавой системы для электроныых деталей |
|
DAC121S101WGRLV датащи(PDF) 7 Page - Texas Instruments |
|
|
DAC121S101WGRLV датащи(HTML) 7 Page - Texas Instruments |
7 / 26 page I/O GND TO INTERNAL CIRCUITRY DAC121S101QML www.ti.com SNAS410E – MAY 2008 – REVISED MARCH 2013 DAC121S101 Electrical Characteristics Radiation Electrical Characteristics (1) The following specifications apply for VA = +2.7 V to +5.5 V, RL = ∞, CL = 200 pF to GND, fSCLK = 20 MHz, input code range 48 to 4047. Sub- Parameter Test Conditions Min Max Units groups POWER REQUIREMENTS Normal Mode 5.5 V 325 µA 1 fSCLK = 20 MHz 3.6 V 250 µA 1 Normal Mode 5.5 V 300 µA 1 fSCLK = 10 MHz 3.6 V 225 µA 1 Normal Mode 5.5 V 275 µA 1 fSCLK = 0 3.6 V 200 µA 1 Supply Current (output IA unloaded) All PD Modes, 5.5 V 125 µA 1 fSCLK = 20 MHz 3.6 V 100 µA 1 All PD Modes, 5.5 V 115 µA 1 fSCLK = 10 MHz 3.6 V 95 µA 1 All PD Modes, 5.5 V 100 µA 1 fSCLK = 0 3.6 V 100 µA 1 (1) Pre and post irradiation limits are identical to those listed in the “DC Parameters” and “AC and Timing Characteristics” tables, except as listed in the “Radiation Electrical Characteristics” table. When performing post irradiation electrical measurements for any RHA level, TA = +25°C. See Radiation Environments for dose rate and test conditions. DAC121S101 Electrical Characteristics Operating Life Test Delta Parameters TA at 25°C (1) Parameter Test Conditions Min Max Units INL Integral non-linearity ±2 LBS ts Output voltage settling time ±5 µA Normal Mode, VA = 5.5V fSCLK = 20 MHz ±10 µA Normal Mode, VA = 3.6V fSCLK = 20 MHz ±6 µA Normal Mode, VA = 5.5V fSCLK = 10 MHz ±10 µA Normal Mode, VA = 3.6V fSCLK = 10 MHz ±6 µA Normal Mode, VA = 5.5V fSCLK = 0 ±8 µA Normal Mode, VA = 3.6V fSCLK = 0 ±6 µA IA Supply Current (output unloaded) All PD Modes, VA = 5.5V fSCLK = 20 MHz ±2 µA All PD Modes, VA = 3.6V fSCLK = 20 MHz ±1 µA All PD Modes, VA = 5.5V fSCLK = 10 MHz ±1 µA All PD Modes, VA = 3.6V fSCLK = 10 MHz ±1 µA All PD Modes, VA = 5.5V fSCLK = 0 ±0.1 µA All PD Modes, VA = 3.6V fSCLK = 0 ±0.1 µA (1) These parameters are worse case drift. Deltas are performed at room temperature Post OP Life. All other parameters no Deltas are required. Figure 2. Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 7 Product Folder Links: DAC121S101QML |
Аналогичный номер детали - DAC121S101WGRLV |
|
Аналогичное описание - DAC121S101WGRLV |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |