10 / 23 page ML15.121 MiniLine-2 12V, 1.3A, SINGLE PHASE INPUT 11. TERMINALS AND WIRING All terminals are easy to access when mounted on the panel. Input and output terminals are separated from each other (input below, output above) to help in error-free wiring. Input Output Type screw terminals screw terminals Solid wire 0.5-6mm2 0.5-6mm2 Stranded wire 0.5-4mm2 0.5-4mm2 American Wire Gauge 20-10 AWG 20-10 AWG Wire stripping length 7mm / 0.275inch 7mm / 0.275inch Screwdriver 3.5mm slotted or Pozidrive No 2 3.5mm slotted or Pozidrive No 2 Recommended tightening torque 1Nm, 9lb.in 1Nm, 9lb.in Instructions: a) Use appropriate copper cables that are designed for minimum operating temperatures of: 60°C for ambient up to 45°C and 75°C for ambient up to 60°C minimum. b) Follow national installation codes and installation regulations! c) Ensure that all strands of a stranded wire enter the terminal connection! d) Up to two stranded wires with the same cross section are permitted in one connection point (except PE wire). e) Do not use the unit without PE connection. f) Screws of unused terminal compartments should be securely tightened. g) Ferrules are allowed. 12. LIFETIME EXPECTANCY AND MTBF These units are extremely reliable and use only the highest quality materials. The number of critical components such as electrolytic capacitors has been reduced. AC 100V AC 120V AC 230V Lifetime expectancy *) 123 000h 126 000h 125 000h at 12V, 1.3A and 40°C > 15 years > 15 years > 15 years at 12V, 0.65A and 40°C > 15 years > 15 years > 15 years at 12V, 1.3A and 25°C MTBF **) SN 29500, IEC 61709 3 435 000h 3 723 000h 3 811 000h at 12V, 1.3A and 40°C 5 633 000h 6 106 000h 6 205 000h at 12V, 1.3A and 25°C MTBF **) MIL HDBK 217F 1 482 000h 1 534 000h 1 451 000h at 12V, 1.3A and 40°C; Ground Benign GB40 1 986 000h 2 056 000h 1 944 000h at 12V, 1.3A and 25°C; Ground Benign GB25 *) The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The prediction model allows only a calculation of up to 15 years from date of shipment. **) MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it can not be determined if the failed unit has been running for 50 000h or only for 100h. Mar. 2013 / Rev. 2.1 DS-ML15.121-EN All parameters are specified at 12V, 1.3A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 10/23 |
Аналогичный номер детали - ML15.121 |
|
Аналогичное описание - ML15.121 |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |