поискавой системы для электроныых деталей |
|
VMS-180-15 датащи(PDF) 2 Page - CUI INC |
|
VMS-180-15 датащи(HTML) 2 Page - CUI INC |
2 / 6 page cui.com date 09/05/2017 │ page 2 of 6 CUI Inc │ SERIES: VMS-180 │ DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description min typ max units voltage 80 264 Vac frequency 47 63 Hz current at 115 Vac, full load at 230 Vac, full load 2.2 1.1 A A inrush current at 230 Vac, cold start 45 A leakage current at 230 Vac 0.3 mA touch current 0.1 mA power factor at full load 0.95 no load power consumption 0.5 W input fuse 6.3 A/250 V time delay fuse (included) OUTPUT parameter conditions/description min typ max units initial set point accuracy ±1 % line regulation ±0.5 % load regulation from 100% to 10% load ±1 % start-up delay time 2 s rise time at 115/230 Vac 55 ms hold-up time at 115/230 Vac 10 ms adjustability1 built in trim pot ±3 % switching frequency 50 300 kHz transient response 25% step load change, at 0.1 A/µS slew rate, 50% duty cycle, 50/60 Hz, max excursion 4%, recovery time 5 ms temperature coefficient at 0~50°C ±0.05 %/°C fan output2 12 Vdc / 500 mA Notes: 1. Adjustment potentiometer is located on the SMT side of the PCB. 2. Fan supply output voltage tolerance including set point accuracy, line and load regulation is ±10% and ripple and noise is less than 10%. PROTECTIONS parameter conditions/description min typ max units over voltage protection hiccup, auto recovery 110 140 % over current protection hiccup, auto recovery 110 % short circuit protection hiccup, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output (2 x MOPP) input to ground (1 x MOPP) output to ground 4,200 1,500 1,500 Vac Vac Vac safety approvals IEC 60601-1: 2005 +CORR1:2006 +CORR2:2007 +AM1:2012, EN 60601-1:2006 +A11:2011 +A1:2013, ANSI/AAMI ES 60601-1 (2005+CI:09+A2:10), AMD1:2012 CAN/CSA- C22.2 No 60601-1 (2008) 60601-1:14 ISO 14971, 2nd edition complies with LVD directive safety class class I conducted emissions EN 55011 Class B Notes: 3. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. For more information, please visit the product page | If your application requires forced air, view our Dc Fans |
Аналогичный номер детали - VMS-180-15 |
|
Аналогичное описание - VMS-180-15 |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |